信息内容由网友发布,本站并不对内容真实性负责,请自鉴内容真实性。

CSD-601智能终端说明书(0SF.452.057)_V1.10

日期: 2024-03-25 22:52:31|浏览: 235|编号: 6

友情提醒:信息内容由网友发布,本站并不对内容真实性负责,请自鉴内容真实性。

CSD-601智能终端说明书


目 录
1 装置概述 ................................................................................................................1
2 产品型号及参数 ....................................................................................................2
2.1 产品型号 ........................................................................................................2
2.2 型式及分类.....................................................................................................2
2.3 额定参数 ........................................................................................................2
2.3.1 交/直流电源................................................................................................2
2.3.2 开关量开入开出 .........................................................................................2
3 硬件说明 ................................................................................................................4
3.1 机箱尺寸 ........................................................................................................4
3.2 背板端子 ........................................................................................................5
3.3 主 CPU 插件 ...................................................................................................6
3.4 从 CPU 插件 ...................................................................................................6
3.5 直流测量插件 .................................................................................................7
3.5.1 跳线说明.....................................................................................................7
3.5.2 通道位置及类型设置 .................................................................................8
3.5.3 端子接线.....................................................................................................9
3.6 DI 插件(开入插件) ....................................................................................... 10
3.7 DO 插件(开出插件)...................................................................................... 12
3.8 DIO 插件 ......................................................................................................14
3.9 DIO 扩展插件(操作插件)........................................................................ 16
3.9.1 合闸插件................................................................................................... 17
3.9.2 跳闸 I 插件 ............................................................................................... 18
3.9.3 跳闸 II 插件 .............................................................................................. 19
3.10 电源插件 ...................................................................................................... 20
3.11 面板 ..............................................................................................................21
4 逻辑运算功能 ........................................................................................................1
5 使用注意事项 ........................................................................................................5
6 维护运行注意事项.................................................................................................5
6.1 常见异常情况及对策 .....................................................................................5
6.2 部分检查项目 .................................................................................................5
7 运输、贮存注意事项 .............................................................................................5
8 订货须知 ................................................................................................................5
附录一 合闸插件内部说明 ...........................................................................................6
附录二 跳闸插件内部说明 ...........................................................................................7
CSD-601
智能终端
说明书
1
1 装置概述
CSD-601 智能终端主要用于数字化及智能化变电站系统,属过程层设备。能够完成
所在间隔的信息采集、控制以及部分保护功能,包括断路器、隔离刀闸、接地刀闸的监
视和控制。
(1) 装置显示
本装置采用基于 PC 的以太网外接显示软件作为调试手段,同时装置面板具备 LED
指示灯。
(2) 遥信
每组开入可以定义成多种输入类型,如状态输入(重要信号可双位置输入)、告警
输入、事件顺序记录(SOE)、主变分接头输入等。
(3) 保护跳合闸
可接收保护装置下发的跳闸、重合闸命令,完成保护跳合闸。
(4) 控制命令
接收测控装置转发的主站遥控命令,完成对断路器及其相关刀闸的控制。
(5) 温度采集
本装置可采集多种直流量,如 DC0V~5V、DC4mA~20mA 等,还能完成主变温度
的采集上送。
CSD-601
智能终端
说明书
2
2 产品型号及参数
2.1 产品型号
产品型号“CSD-601”后面跟着的 1 位字母为子型号,其含义如下:
表 2-1 末尾字母含义
字母 含义
A 分相断路器智能终端
B 三相断路器智能终端
C 本体智能终端
面板印字只包括产品型号“CSD-601”,没有标示后面的子型号。
2.2 型式及分类
(1) 构成原理为微机型。
(2) 安装方式为嵌入安装。
(3) 结构型式为插入式结构。
(4) 接线方式为后接线方式,各插件之间用母板印制板连接。
(5) 输入激励量类型为交流、直流。
(6) 按机箱外形尺寸的不同,分为 19/2 英寸机箱和 19 英寸机箱,机箱高度为 4U。
2.3 额定参数
2.3.1 交/直流电源
1) 交流电源电压为单相 220V,电压允许偏差-20%~+15%;
2) 交流电源频率为 50Hz 允许偏差±5%;
3) 交流电源波形为正弦波,谐波含量小于 5%;
4) 直流电源电压为 110V 或 220V,允许偏差为-20%~+15%;
5) 直流电源电压纹波系数小于 5%;
6) 额定直流电压输出:+5V、±12V、+24V(1)(用于产品内部开出);+24V(2)(供
外部开入使用)。
2.3.2 开关量开入开出
1) 开关量输入:最大路数为 90 路
2) 输入电压:DC220V/110V
3) 开关量输出:最大路数为 56 路